Reactor agitator design: rpm, power and shaft checks

Glass-lined reactor vessels on the shop floor
Glass-lined reactor workshop — the equipment this article is about.

Reactor agitator design is calculated in three steps: select the impeller from viscosity, set the speed in rpm from the mixing duty, and calculate shaft power in kW from P = Np ρ N³ D⁵; then check the shaft diameter in mm in torsion and the first critical speed in rpm. The result must be issued on the general arrangement drawing and approved against the specification confirmation sheet, with design pressure in MPa and seal type fixed, before fabrication starts.

1. Pick the impeller before you argue about rpm

Impeller type sets the flow pattern, and the flow pattern sets the usable speed window. For a reactor agitator design calculation, the sequence is impeller → speed → power → shaft, not motor kW → rpm → impeller.

Use the product list you already have: paddle, anchor/frame, disc turbine, hydrofoil, impeller and dispersion disc. A hydrofoil or pitched-blade impeller is for bulk blending at low viscosity. A disc turbine or dispersion disc is for gas-liquid contact and high shear. An anchor or frame is for high viscosity and heat transfer at the wall. A paddle is a gentle low-shear choice, not a universal default.

Viscosity is the first divider. As a starting window, not a guarantee: below about 100 mPa·s, 150–400 rpm; 100–1,000 mPa·s, 60–150 rpm; 1,000–10,000 mPa·s, 30–60 rpm; above 10,000 mPa·s, 10–30 rpm with an anchor or frame. These bands move with density, solids, gas rate, baffles and the required blend time. The approved drawing must carry the calculated values, not the band.

2. Set rpm from duty, then convert it correctly

Speed in rpm is a process decision. It comes from the required tip speed, blend time or heat-transfer coefficient, not from the motor nameplate. For a given impeller diameter D in metres, tip speed is πDN/60 in m/s when N is in rpm. If the duty needs a tip speed of 2 m/s and D is 0.4 m, the arithmetic gives about 95 rpm; if D is 0.6 m, the same tip speed gives about 64 rpm.

The common error is putting rpm straight into the power equation. P = Np ρ N³ D⁵ needs N in revolutions per second. A 120 rpm speed is 2.0 r/s. Using 120 instead of 2.0 makes the calculated power 216,000 times too large. That single unit mistake is enough to turn a 4 kW duty into a nonsense number.

3. Power: demand Np, do not borrow it

In P = Np ρ N³ D⁵, P is shaft power in W, ρ is density in kg/m³, N is speed in r/s and D is impeller diameter in m. Np is the power number, and it is not a constant. It changes with impeller geometry, baffle arrangement, Reynolds number and gas rate.

Ask the supplier for Np at your operating viscosity and baffle geometry. A hydrofoil and a disc turbine do not share a power number, and a disc turbine in a gassed vessel does not share the ungassed value. If a quotation gives motor kW but not shaft kW, treat the power calculation as unfinished. Motor kW includes drive efficiency and seal losses; shaft kW is what the impeller actually receives.

The specification should state impeller diameter in mm, speed in rpm, shaft power in kW and motor kW separately. If two of those four are missing, the agitator is not specified.

4. Shaft diameter: torsion, bending and the keyway

Shaft diameter in mm is not scaled from motor kW. It is checked for torsional shear from the impeller torque, bending from hydraulic thrust, and stress concentration at the keyway or coupling. For a solid round shaft, the nominal shear stress is τ = 16T/(πd³), with T in N·m and d in m; the allowable value comes from the shaft material, design temperature in °C and corrosion allowance.

A long shaft with a heavy impeller also needs a bending check. Glass-lined shafts add a hard, brittle outer layer, so the shaft and impeller are fixed before lining. No welding is done after the lining is fired. That is why a late change from a paddle to a disc turbine is not a small revision.

5. Critical speed: the pitfall that shows up at 2 a.m.

The first critical speed is the shaft's natural lateral frequency in rpm. It depends on shaft length, diameter, impeller mass, bearing span and any bottom steady bearing. A common specification asks for the first critical speed to be at least 20% above the maximum operating speed. If the shaft is long and slender, the operating window may sit below the first critical speed, and a larger shaft or a steady bearing is required.

Do not accept a critical-speed calculation that omits the impeller mass, the glass lining or the seal cartridge. Do not accept one that uses a generic shaft length instead of the general arrangement drawing. The check is cheap before fabrication and expensive after the vessel is lined.

6. What goes on the data sheet

Put these on one sheet and make the supplier answer each line: viscosity at operating temperature in mPa·s, density in kg/m³, solids content and particle size, gas rate if any, impeller type and diameter in mm, speed range in rpm, shaft power in kW, motor kW, shaft diameter in mm, first critical speed in rpm, baffle arrangement, seal type and design pressure in MPa. For glass-lined build, add lining thickness in mm and high-voltage test in kV. The numbered specification confirmation sheet is the document you approve; the drawing must match it.

The honest trade-off: a larger impeller at lower rpm can give the same blend with lower shear, but it needs more torque and a larger shaft. A smaller impeller at higher rpm is cheaper on shafting but can damage shear-sensitive crystals or the glass lining. Neither is automatically right. The duty decides.

Takeaway

Do the calculation in the right order: impeller from viscosity, rpm from duty, kW from P = Np ρ N³ D⁵ with N in r/s, then shaft diameter and first critical speed. Ask for Np, shaft kW and the critical-speed margin in writing. If the quotation cannot show those numbers on the general arrangement drawing, the agitator is still a catalogue guess.

Send us your duty. We'll send you a specification.

No obligation and no sales sequence. Tell us what you are trying to make, and we will tell you what it takes — vessel, material, limits and price.

Message Alex on WhatsApp